PhalangeRestaurant Inspection Lookup

Boston inspection record for Chop Chop Rice Thai Cuisine (248 NEWBURY ST)

Latest inspection: Nov 12, 2026 · Failed

Boston's feed records each inspection's outcome only — the city publishes no score or letter grade in this data, so none is shown or reconstructed.

5 recorded inspections in Boston — the full stored timeline, newest first, with the latest inspection's violation items — from the city's official open data.

Start with the result-producing visit, then read its recorded outcome alongside available citations and separately documented follow-ups.

Data synced Nov 27, 2026 · newest inspection city-wide Nov 25, 2026

Source: City of Boston Inspectional Services Department inspection records. Records as of Nov 25, 2026. An inspection is a snapshot of one day.

248 NEWBURY ST, BOSTON MA 02116

License no. 613086

Category Eating & Drinking w/ Take Out

What the record shows

There are not enough classifiable inspections in both periods to describe a trend. You can still read the individual records below.

The outcome recorded on Nov 12, 2026 was Failed, the same as on Nov 2, 2026. The cited findings may differ; read both reports.

Inspection history

  1. LatestFailed

    2 violation items in this inspection

    Backflow Prevention (P)***
    590.005/5-402.11-P · Pass

    10-15-2026 work has been done at the prep sink but a permit has not been given yet; have your licensed plumber pull permits at 1010 Mass Ave and provide the permit from the City Plumbing Inspector as soon as possible.

    Floors Walls and Ceilings Utility Lines (C)*
    590.006/6-201.12-C · Fail

    Observed at the food prep areas above the warewashing areas that there are exposed pipes or utility lines; per the plan review it states that these are to be enclosed; provide enclosed utility lines or pipes.

  2. Failed

    2 violation items in this inspection

    Backflow Prevention (P)***
    590.005/5-402.11-P · Fail

    10-15-2026 work has been done at the prep sink but a permit has not been given yet; have your licensed plumber pull permits at 1010 Mass Ave and provide the permit from the City Plumbing Inspector as soon as possible.

    Floors Walls and Ceilings Utility Lines (C)*
    590.006/6-201.12-C · Fail

    Observed at the food prep areas above the warewashing areas that there are exposed pipes or utility lines; per the plan review it states that these are to be enclosed; provide enclosed utility lines or pipes.

  3. Failed

    4 violation items in this inspection

    Handwashing Sinks-Numbers and Capacities (Pf)**
    590.005/5-203.11-PF · Pass

    Approved stamped plans on site indicate a handsink should be located next to the ice machine at the serving line. That handsink was found not to be installed upon today's inspection. Install working handsink according to approved plans. Provide copy of a ISD plumbing permit.

    Backflow Prevention (P)***
    590.005/5-402.11-P · Fail

    10-15-2026 work has been done at the prep sink but a permit has not been given yet; have your licensed plumber pull permits at 1010 Mass Ave and provide the permit from the City Plumbing Inspector as soon as possible.

    Floors Walls and Ceilings Utility Lines (C)*
    590.006/6-201.12-C · Fail

    Observed at the food prep areas above the warewashing areas that there are exposed pipes or utility lines; per the plan review it states that these are to be enclosed; provide enclosed utility lines or pipes.

    Outer Openings Protected (C)*
    590.006/6-202.15-C · Pass

    Front glass door with gaps at top and bottom sides of door. Seal with pest proof materials.

  4. Failed

    5 violation items in this inspection

    Handwashing Sinks-Numbers and Capacities (Pf)**
    590.005/5-203.11-PF · Fail

    Approved stamped plans on site indicate a handsink should be located next to the ice machine at the serving line. That handsink was found not to be installed upon today's inspection. Install working handsink according to approved plans. Provide copy of a ISD plumbing permit.

    Backflow Prevention (P)***
    590.005/5-402.11-P · Fail

    10-15-2026 work has been done at the prep sink but a permit has not been given yet; have your licensed plumber pull permits at 1010 Mass Ave and provide the permit from the City Plumbing Inspector as soon as possible.

    Toilet Room Receptacle Covered (C)*
    590.005/5-501.17-C · Pass

    Provide covered receptacle in one of two restrooms.

    Floors Walls and Ceilings Utility Lines (C)*
    590.006/6-201.12-C · Fail

    Observed at the food prep areas above the warewashing areas that there are exposed pipes or utility lines; per the plan review it states that these are to be enclosed; provide enclosed utility lines or pipes.

    Outer Openings Protected (C)*
    590.006/6-202.15-C · Fail

    Front glass door with gaps at top and bottom sides of door. Seal with pest proof materials.

  5. Failed

    4 violation items in this inspection

    Handwashing Sinks-Numbers and Capacities (Pf)**
    590.005/5-203.11-PF · Fail

    Approved stamped plans on site indicate a handsink should be located next to the ice machine at the serving line. That handsink was found not to be installed upon today's inspection. Install working handsink according to approved plans. Provide copy of a ISD plumbing permit.

    Backflow Prevention (P)***
    590.005/5-402.11-P · Fail

    The food prep sink drain pipe does not have a seperation gap. Install. Provide copy of ISD plumbing permit from a licensed plumber.

    Toilet Room Receptacle Covered (C)*
    590.005/5-501.17-C · Fail

    Provide covered receptacle in one of two restrooms.

    Outer Openings Protected (C)*
    590.006/6-202.15-C · Fail

    Front glass door with gaps at top and bottom sides of door. Seal with pest proof materials.